Skip to content
Open access

A real-time metric for quantifying registration stability in mixed reality neurosurgical navigation.

Sep 2026 · International Journal of Computer Assisted Radiology and Surgery · 0 citations · 18 references
Medicine

TL;DR

As a technical proof of concept, RQI enables continuous, automated monitoring of registration stability in MR-guided neurosurgical navigation, addressing a critical limitation of current static accuracy assessments.

Abstract

Objective

Mixed reality (MR) guidance enables real-time superimposition of virtual anatomical models onto the surgical field but is inherently affected by spatial instability due to tracking limitations, sensor noise and head-mounted display dynamics. These frame-to-frame fluctuations may lead to transient mislocalisation of neuroanatomical structures and are not adequately captured by conventional static registration metrics. This study aimed to develop and validate a clinically interpretable metric for continuous assessment of registration stability in MR-guided neurosurgery.

Methods

The Registration Quality Index (RQI) was introduced as an automated, surface-based metric quantifying virtual-physical alignment through pixel-level boundary proximity analysis. A higher RQI value indicates greater boundary displacement, corresponding to worse registration quality. Validation was performed using a rigid skull phantom, a Varjo XR-3 mixed reality headset and ArUco-based optical tracking across fifteen experimental trials and seventy-five viewing configurations. RQI values were compared with established neuronavigation accuracy metrics, including Fiducial Registration Error (FRE) and Target Registration Error (TRE).

Results

Strong correlations were observed between RQI and FRE (r = 0.89 (95% CI 0.69-0.96), p < 0.001) and between RQI and TRE (r = 0.93 (95% CI 0.80-0.98), p < 0.001). Regression analysis demonstrated that each 1% increase in RQI corresponded to a 0.195 mm increase in FRE and a 0.244 mm increase in TRE. Real-time computation at 30 Hz was achieved without workflow disruption. RQI variability was significantly influenced by viewing angle, with lateral perspectives yielding higher displacement values than frontal views.

Conclusions

As a technical proof of concept, RQI enables continuous, automated monitoring of registration stability in MR-guided neurosurgical navigation, addressing a critical limitation of current static accuracy assessments. While the current proof-of-concept validation on rigid phantoms demonstrates strong construct validity, the interpretability ranges reported here are exploratory and further clinical studies involving in vivo conditions are required to establish clinically actionable decision boundaries and assess performance in the presence of brain shift and soft tissue deformation.

Read PDF

Similar papers

Conference Open access 2026

Development Of A Mixed Reality–Based Organ Registration Assistance System For CT-Guided Puncture

Extended Reality (XR) technologies have been increasingly applied in the medical field, particularly for supporting image-guided interventions. In CT-guided biopsy, accurate puncture requires repeated CT imaging to confirm the insertion path, which results in increased radiation exposure for both patients and operators...

T. Kotone, N. Motoki, T. Ikuto et al. · 0 citations
Open access Nov 2026

Evaluating Optimization-Based Image Refinement for 3-D Ultrasound Mosaicking: A Sensitivity Analysis of Clinical and Benchmark Data.

OBJECTIVE This study evaluates the performance and sensitivity of an optimization-based registration framework for mosaicking partially overlapping 3-D ultrasound volumes to expand the clinical field of view. We specifically characterize the algorithm's ability to recover from varying degrees of initial tracking uncert...

M. Antico, S. Mason, E. Harris et al. · 0 citations
Open access Oct 2026

Comparison of the Image-to-Patient Registration Performance of a Novel Augmented Reality-Based and a State-of-the-Art Infrared Optical Neuronavigation System.

BACKGROUND AND OBJECTIVES Augmented reality-based neuronavigation systems (AR-NS) have been proposed as a potential addition to regular neuronavigation systems, such as optical or electromagnetic systems. Accurate image-to-patient registration is a prerequisite for clinical acceptance and implementation of AR-NS in neu...

T. Kos, W. Maathuis, P. Willems et al. · 0 citations
Review Open access Oct 2026

Clinical accuracy and efficiency of augmented reality head-mounted displays in cranial neurosurgery: a systematic review

AR HMD technology is a promising adjunct for cranial neurosurgical navigation, providing clinically useful accuracy comparable to conventional neuronavigation in selected applications while improving spatial orientation, ergonomics, and surgical workflow.

Ahmad Budirahaji, R. I. Susilo, Joni Wahyuhadi et al. · 0 citations
#software testing Open access Oct 2026

AI-assisted versus point-based registration for digital planning in CBCT images with metallic artifacts

AI-assisted registration achieved significantly lower registration discrepancies than conventional point-based registration while maintaining comparable registration duration in CBCTs with metallic artifacts on CBCT images, suggesting that AI-assisted registration may improve the accuracy and consistency of multimodal...

N. Shobair, Z. Abdel-Rahman, Mohamed Ahmed Mohamed Tolba et al. · 0 citations
Oct 2026

DEVELOPMENT OF A NEW IMAGE REGISTRATION-BASED METHOD FOR TRACKING VERTEBRAL MOTION IN KINETIC SAGITTAL MRI

Investigation of the similarity space for the tested parameters indicated that MRI image artefact was the principle reason for similarity minima not corresponding to the correct registration, hence failure of gradient descent optimisation.

K. Brownhill, F. Mellor, C. Heales et al. · 0 citations