Aug 2026· IEEE Transactions on Medical Imaging· Vol PP, pp. 1-1· 0 citations· 48 references
Computer SciencePhysicsMedicine
TL;DR
Results indicate that SSRL-MAR provides a robust and scalable image-domain solution for 3D brain MRI motion correction, enabling reliable structural quantification in large-scale neuroimaging studies without requiring prospectively acquired pairs or acquisition-specific calibration.
Abstract
Patient motion remains a source of image degradation in brain MRI, leading to signal loss, blurring, and geometric distortion that compromise quantitative analysis. Existing deep learning methods for motion correction typically rely on paired clean-corrupted data or k-space acquisitions, which are rarely available in clinical settings. We propose SSRL-MAR, a motion artifact-aware unpaired representation learning framework for motion artifact reduction that requires neither paired training data nor explicit motion labels. SSRL-MAR employed a three-stage training strategy: (1) contrastive learning on 3D patches to extract motion representations by contrasting clean and synthetically corrupted images, (2) a motion artifact-aware synthesis network to generate motion artifacts from clean scans, and (3) a motion artifact-aware generator to restore clean volumes using the learned degrader for self-supervised supervision. On in-silico dataset, SSRL-MAR achieved PSNR 23.81dB, SSIM 91.55%, and NMSE 0.79%. On in-vivo MR-ART dataset, the pretrained model reduced motion distortion, and unsupervised domain adaptation further improved anatomical fidelity. Against a source-only supervised model trained on the same simulated pairs, SSRL-MAR improved PSNR by up to 2.0 dB on MR-ART after unsupervised domain adaptation, and remained within 0.25-0.47 dB of an oracle supervised model that requires real paired data unavailable in practice. At the milder motion level, volumetric error in structures such as the corpus callosum and ventricular system decreased by more than 50%, confirming improved neuroanatomical consistency. These results indicate that SSRL-MAR provides a robust and scalable image-domain solution for 3D brain MRI motion correction, enabling reliable structural quantification in large-scale neuroimaging studies without requiring prospectively acquired pairs or acquisition-specific calibration.
Motion-corrupted inverse problems remain a central bottleneck in magnetic resonance imaging (MRI), especially for high-resolution 3D acquisitions where long readouts couple rigid-body displacement with non-Cartesian k-space sampling. We present a physics-informed implicit neural representation (INR) that recasts 3D mot...
Hao-Yuan Le, Qing Wu, Bo-Wen Li et al.· Medical Image Analysis· 0 citations
Magnetic resonance imaging (MRI) plays an important role in clinical diagnosis, nevertheless, it suffers from motion artifacts in many real-world scenarios. Removing motion artifacts can alleviate this interference and thus facilitate precise diagnosis. However, recent works mainly rely on paired data and the artifactu...
Jia-Hua Xu, Dawei Zhou, Lei Hu et al.· Neural Networks· 0 citations
Background: Four-fold accelerated sensitivity encoding (SENSE4) can shorten brain MRI acquisition time but may amplify noise and result in residual aliasing artifacts after conventional reconstruction. Purpose: To evaluate whether an image-domain refinement framework can improve the quality of SENSE4 brain MRI while pr...
Chang-Jing Chai, Bin Huang, Li-Bo Xu et al.· 0 citations
BACKGROUND
Magnetic resonance (MR) images are essential for clinical diagnosis, yet their quality is often compromised by noise and motion artifacts, potentially obscuring anatomical details and reducing diagnostic accuracy. Existing deep learning approaches frequently address denoising and motion artifact suppression...
Ming-Fu Jiang, Chi-Kin Lam, Zhuo-Neng Zhang et al.· Medical Physics (Lancaster)· 0 citations
This work recast unsupervised MAR as an artifact-consistent residual learning problem and proposes a physically grounded, attention-guided generative framework that closes the loop between artifact estimation and removal.
En-Yu Bao, Yi-Fei Chen, Jun-Hao Ye et al.· IEEE journal of biomedical a...· 0 citations
This study proposes a novel training-free motion correction framework leveraging frozen DINOv3 foundation model features to achieve robust myocardial alignment without task-specific network training or fine-tuning, providing solution for cardiac T1 mapping.
Wanman Li, Qing Chang· Magnetic Resonance Imaging· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.