Jul 2026· Nuclear medicine and molecular imaging· 0 citations· 18 references
TL;DR
It is demonstrated that high-sensitivity systems might significantly shorten protocols without compromising diagnostic integrity, providing a potential rationale for further optimization of imaging protocols and for future prospective studies specifically designed to evaluate whether the administered radiotracer activity can be safely reduced to ultra-low-dose levels while maintaining diagnostic performance.
Abstract
Long axial field-of-view (LAFOV) PET/CT systems provide up to 40-fold higher sensitivity than standard digital systems. This study evaluated the impact of reducing acquisition times in [18 F]DCFPyL (PSMA) total-body PET/CT to support future research on the development of low-dose protocols.
Eighty-five patients with prostate cancer underwent total-body PET/CT on a 194 cm-LAFOV system. Standard 8-minute list-mode acquisitions were retrospectively reconstructed into 6-, 4-, and 2-minute datasets. In a subgroup of thirty-three consecutive patients, two experts independently assessed image quality (5-point Likert scale) and E-PSMA criteria. Quantitative analysis (SUVmax, SUVmean) was performed for primary, nodal, and bone lesions.
In the whole dataset (
n
= 85) the lesion detection rate (90.5%) and classification consistency between readers and across acquisition times exceeded 95% and remained stable between the 8-minute and 2-minute reconstructions. In a sub-group of thirty-three, no significant differences were found in quantitative parameters across all acquisition times (
p
> 0.05). While image quality scores improved slightly with longer durations (ranging from 4.50 at 2 min to 4.82 at 8 min), lesion visibility remained high even at 2 min. Changes in physiological background uptake did not impact lesion quantification.
The preliminary results of the study suggest that LAFOV-PSMA-PET/CT preserves quantitative accuracy and lesion detectability even with acquisition times reduced to 2–4 min. These findings demonstrate that high-sensitivity systems might significantly shorten protocols without compromising diagnostic integrity, providing a potential rationale for further optimization of imaging protocols and for future prospective studies specifically designed to evaluate whether the administered radiotracer activity can be safely reduced to ultra-low-dose levels while maintaining diagnostic performance.
These findings support further evaluation of liver-referenced thresholding for standardized PSMA-TV assessment in longitudinal and multicenter settings and support further evaluation of liver-referenced thresholding for standardized PSMA-TV assessment in longitudinal and multicenter settings.
Ellen Schötz, D. Ufton, J. Weindler et al.· Annals of Nuclear Medicine· 0 citations
The OSEM + PSF + TOF reconstruction method demonstrated significant advantages in both image quality and quantitative assessment of FDG uptake, making it the recommended choice for spinal cord PET image reconstruction.
Ji-Yuan Wang, Jing Huang, B. Cui et al.· EJNMMI Physics· 0 citations
This study investigated the relationship between body size, administered activity, and image quality (IQ) using two patient-like phantoms representing normal and obese body profiles, and demonstrated the count rate capabilities up to and beyond the saturation limit.
Nanna Overbeck, Zuzanna Czeluśniak, Søren Holm et al.· Physics in Medicine and Biol...· 0 citations
PURPOSE
The purpose of this study was to compare the image quality and lesion detection between ultra-low dose (ULD) chest-abdomen-pelvis computed tomography (CAP-CT) reconstructed with a deep-learning image reconstruction (DLR) algorithm, and standard-dose CT (STD-CT) in cancer follow-up.
MATERIALS AND METHODS
A tot...
F. de Oliveira, Sinda Ghabri, Souha Benhalilou et al.· Diagnostic and Interventiona...· 0 citations