Skip to content
Open access

A Monolithic, Thiol-Functionalized Au-Based Bio-CMOS Aptasensor for Rapid, Label-Free Detection of Escherichia coli O157:H7 in Patient-Derived and Hospital-Acquired Specimens

Zahra Nejad Shahrokh Abadi M. H. Shahrokh Abadi Reza Nejad Shahrokh Abadi
Jul 2026 · Bioengineering · Vol 13, pp. 858 · 0 citations · 33 references
Medicine

TL;DR

Because the patient-derived and hospital-acquired cohorts were assembled for pilot analytical and matrix-tolerance characterization rather than for diagnostic-accuracy determination, these results establish detectability and matrix robustness in real clinical and environmental specimens rather than clinical diagnostic sensitivity or specificity.

Abstract

Rapid, point-of-care detection of Escherichia coli O157:H7 remains an unmet clinical need, as culture and molecular methods are slow and poorly suited to decentralized or emergency settings. A label-free, monolithic aptasensor biochip was fabricated in a standard 65 nm CMOS process, featuring three aptamer-functionalized gold sensing pads with matched reference pads for differential readout. A 37-mer DNA aptamer targeting the E. coli O157:H7 lipopolysaccharide was immobilized via thiol–gold self-assembled monolayer chemistry. Binding events were transduced into surface-potential shifts, amplified by an on-chip analog front-end (~100 V/V gain, 101.5 µW), and evaluated using calibration standards, patient specimens, and hospital environmental samples, with fluorescence microscopy for validation. The sensor achieved 47.42 mV/decade sensitivity across 1–10,000 CFU/mL, an IUPAC detection limit near 3.74 CFU/mL, and an empirical LOD of about 11 CFU/mL, with outputs tracking bacterial load and ~5.7% matrix-related deviation. Hospital samples were detectable to 28 CFU/mL. Because the patient-derived and hospital-acquired cohorts (n = 10 and n = 6, respectively) were assembled for pilot analytical and matrix-tolerance characterization rather than for diagnostic-accuracy determination, these results establish detectability and matrix robustness in real clinical and environmental specimens rather than clinical diagnostic sensitivity or specificity, which will require a larger, prospectively enrolled cohort in future work. Sensor kinetics followed Langmuir-type adsorption, saturating within 16–25 min for target pathogens versus slower responses for non-target strains. Selectivity tests against six bacterial species showed discrimination, with cross-reactivity decreasing from related E. coli pathotypes to Enterobacteriaceae to Gram-positive species. Inter-pad variability stayed below 1.5 mV, supporting this compact, low-power platform for scalable, enrichment-free point-of-care pathogen detection.

Read PDF

Similar papers

Sep 2026

Disposable label-free electrochemical immunosensor using hollow porous gold sub-microcubes with surface-confined ferrocene for point-of-care detection of Mpox virus A29 protein.

Monkeypox (Mpox), a viral zoonotic disease caused by the monkeypox virus (MPXV) remains a significant global public health concern. Current laboratory diagnostics are limited by high biosafety requirements and complex workflows, preventing point-of-care (POC) use. To address these limitations, a disposable, label-free...

Md. Mahbubur Rahman Khan, Balamurugan Thangavel, Hyounhwa Kang et al. · 0 citations
#protein folding Oct 2026

All-printed immunosensing microchip for fast and sensitive detection of urinary soluble Fms-like tyrosine kinase-1 in preeclampsia diagnosis.

We present an all-printed immunosensing microchip that integrates hydrophilic-hydrophobic patterning, covalent antibody immobilization, and photonic bandgap engineering into a single, scalable manufacturing platform for high-sensitivity protein detection. By precisely matching the microchip's photonic bandgap (centered...

M. Zeng, Xiao-Long Xu, Xu-Yun Liu et al. · 0 citations
Open access Sep 2026

Streptavidin-Displaying E. coli Scaffolds Enable Target-Mediated Gold Nanoparticle Assembly for Colorimetric Biosensing

This study provides a proof of concept for leveraging engineered living cells as multifunctional nanostructured templates and the modular, plug-and-play architecture of the biotin-streptavidin coupling interface highlights its potential for adaptation to clinical diagnostics and environmental monitoring.

Po-Chih Wu, Shi-Yu Tseng, Shao-Yi Hou et al. · 0 citations
Oct 2026

A-382 Rapid, amplification-free DNA detection from undiluted plasma on dry-printed CNT electrodes via enzymatic chronoamperometry readout

Point-of-care (PoC) facilities need nucleic-acid assays that can shorten turnaround time and simplify workflow while maintaining analytical performance in realistic matrices. We describe a materials-driven electrochemical platform based on floating catalyst chemical vapor deposition-synthesized continuous carbon...

Eero Gustafsson, Samuel Rantataro, Jane Besong-Ndika et al. · 0 citations
Aug 2026

An aptamer-guided flow-cytometric biosensor for simultaneous sizing and polymer identification of nanoplastics.

Nanoplastics are an emerging class of environmental contaminants whose analysis is limited by the difficulty of resolving both particle size and polymer identity at the submicrometre scale in a single high-throughput measurement. Here, a dual-parameter flow-cytometric biosensor was developed that combined polymer-selec...

Hakan Eligul, Murat Kavruk, A. Dursun et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.