Dentinal Tubule Penetration of Various Root Canal Sealers after Removal of Calcium Hydroxide Intracanal Medicament: An In Vitro Confocal Laser Scanning Microscopic Study
Bioroot RCS bioceramic sealer was superior to AH Plus resin-based and Apexit Plus CH-based sealers regarding penetration depth into dentin after removal of CH intracanal medicament.
Abstract
Objectives: This study compared the penetration depth of three different root canal sealers—AH Plus resin-based, Apexit Plus calcium hydroxide (CH)-based, and BioRoot RCS bioceramic-based sealers—into dentin after removal of CH intracanal medicament.
Materials and Methods: In this in vitro study, 60 extracted single-rooted mandibular premolars were decoronated with a diamond disc under water cooling to a standard length of 16mm; 12 samples were selected as control, and the rest received CH mixed with rhodamine dye as an intracanal medicament. Two weeks later, CH was removed by manual filing and irrigant activation using EndoActivator. Samples were then divided into 3 groups (n=12) depending upon the sealer used as AH Plus, Apexit Plus, and Bioroot RCS sealer. All sealers were combined with fluorescein dye, and obturation was performed using F3 gutta-percha with lateral compaction technique. After 2 weeks, the teeth were transversally sectioned into coronal, middle, and apical thirds. The penetration depth of sealers was measured via an imaging software. Statistical analysis was performed using ANOVA followed by the Tukey’s post-hoc test (alpha=0.05).
Results: A statistically significant difference was observed among the groups (P<0.05). The penetration depth of sealers was the lowest in the apical third, and the highest in the coronal third in all three groups. BioRoot RCS showed the highest penetration depth at all three levels, despite CH medicament remnants.
Conclusion: Bioroot RCS bioceramic sealer was superior to AH Plus resin-based and Apexit Plus CH-based sealers regarding penetration depth into dentin after removal of CH intracanal medicament.
Three-dimensional seal of the root canal improvises the endodontic outcomes. Recent trend has shown influential outcomes with single-cone bioceramic sealers. Hence, the present study aimed to evaluate and compare the dentinal tubule penetration of AH plus, BioRoot root canal sealer (RCS), and an experimental bioa...
Poulomi Guha, Pradeep Solete, Nishitha Arun et al.· Saudi Endodontic Journal· 0 citations
Background: Successful root canal treatment depends on achieving an effective three-dimensional seal and limiting microbial persistence and reinfection. Dentinal tubule penetration may enhance sealing by increasing sealer–dentin contact and micromechanical retention. This study compared the dentinal tubule penetration...
Israa Ashkar, J. Sanz, L. Forner et al.· Dental journal· 0 citations
Purpose This in vitro study aimed to assess the penetration of root canal sealer (RCS) into dentinal tubules after the application of an intracanal medicament in hydrogel form (BA) and the effect of irrigation activation methods for its removal using a stereomicroscope. Materials and Methods A total of 135 mandibular s...
D. Nalbantoğlu, Ahmet Mert Nalbantoğlu, Elif Bolat· European Oral Research· 0 citations
UA significantly improved both sealer penetration and bond strength and PCS demonstrated the weakest performance in both parameters, whereas PCS demonstrated the weakest performance in both parameters.
G. P. Sre, D. Chakravarthy, A. Senthilkumar et al.· Endodontology· 0 citations
Abstract Objective The aim of this study is to evaluate the time-dependent volumetric changes, push-out bond strength (POBS), and dentine adaptation of epoxy resin, silicone bioactive glass and calcium silicate root canal sealers over 60 days. Materials and methods One hundred and twenty-five mandibular premolars were...
Thanh Quang Nguyen, Pinpana Thaweesit, Kanet Chotvorrarak et al.· European Journal of Dentistr...· 0 citations
In vitro findings indicate that interfacial gap behavior is better characterized at the product and root-segment level than by nominal material classification; however, they are morphological and should not be read as evidence of overall adaptation, leakage resistance or clinical superiority.
E. Bardakçı, Tuba Doğan· Applied Sciences· 0 citations
Related blog posts
MIT News · Artificial Intelligence· news.mit.eduOct 22, 2026
“X-Hinges” helps design and 3D print items like lamps and gloves with an interactive twist: automatically embedded sensors that perceive and adaptively respond to human contact.
StudentSim is a research system for evaluating and improving AI tutoring tools before they are tested with learners. It models how individuals may engage with tutors, giving feedback to improve tutor performance across subjects like chess, writing, and mathematics. The post Simulating student learning for better AI tutoring appeared first on Microsoft Research.
MIT News · Artificial Intelligence· news.mit.eduOct 6, 2026