Aug 2026· Biomechanics· Vol 6, pp. 72· 0 citations· 31 references
TL;DR
A substantial control-based increase in the available static actuator output and the ability of the prototype to execute prescribed ankle-angle trajectories under controlled bench conditions are demonstrated.
Abstract
Background/Objectives: Lower-limb impairment can alter ankle-joint motion and reduce functional mobility during demanding locomotor tasks such as stair ascent and descent. This study presents the development and preliminary proof-of-concept evaluation of a BLDC-driven active ankle prosthesis incorporating a spherical gear coupling. Methods: Ankle kinematics were recorded using the CONTEMPLAS motion analysis system for one healthy participant and one participant with impaired lower-limb function during level walking, stair ascent, and stair descent. The resulting ankle-angle trajectories were used as reference profiles for unloaded bench testing of the prototype. Results: Static torque was measured using a handheld dynamometer and a fixed lever arm of 0.10 m. Adjustment of the BLDC controller parameters increased the measured static prototype torque from 0.44 N·m to 6.38 N·m, corresponding to a 14.5-fold increase relative to the initial controller configuration, without modification of the mechanical architecture. Under unloaded fixed-rig conditions, the prototype executed a prescribed cyclic ankle-angle trajectory within a range of 112–132°, corresponding to an amplitude of approximately 20°. The optimized prototype torque remained below the 17.17 N·m obtained from a preliminary static measurement of the healthy participant; however, this value should not be interpreted as a physiological torque requirement for dynamic locomotion. Conclusions: The results demonstrate a substantial control-based increase in the available static actuator output and the ability of the prototype to execute prescribed ankle-angle trajectories under controlled bench conditions. Further validation will require dynamic loading, kinetic measurements, foot–ground interaction, improved control strategies, and human-in-the-loop testing with individuals with lower-limb amputation.
Stair ascent is a biomechanically demanding activity for individuals with transfemoral amputation, often requiring significant overreliance on the residual hip and sound biological joints to compensate for the lack of positive power in conventional passive prostheses. Although powered prostheses can generate positive p...
Clare Severe, Lukas Gabert, Grace R. Hunt et al.· IEEE transactions on neural...· 0 citations
Powered lower-limb exoskeletons hold promise for providing locomotion assistance to physically weak individuals, thereby enhancing their quality of life. However, ensuring the balance and safety of the human-robot system during dynamic walking remains a significant challenge for these robots, particularly under unexpec...
Natural ankle quasi-stiffness describes the joint's resistance to motion during loading in gait, which is informative for the design of biomimetic devices (eg, prostheses, orthoses, and exoskeletons). Ankle quasi-stiffness is typically quantified as the slope of the moment-angle curve using a linear approximation. Yet,...
Emma R. Caringella, Kota Z. Takahashi· Journal of Applied Biomechan...· 0 citations
Background The sit-to-stand (STS) task is a fundamental functional movement requiring substantial lower-limb joint torque and coordinated neuromuscular control. The knee joint plays a dominant role in generating extensor torque during the body elevation phase. However, existing exoskeleton assistive strategies often la...
Feng Feng, Yang Yu, Kui Du et al.· Frontiers in Physiology· 0 citations
This study presents the design and preliminary bench evaluation of a sensor-integrated prosthetic-leg prototype. The platform combines a multi-material PAHT-CF/TPU 95A foot, articulated knee and ankle mechanisms, two surface electromyography channels, an MPU6050 inertial measurement unit, an Arduino Uno controller, and...
Turar Seitkassymov, Y. Nurgizat, N. Zhetenbayev et al.· Italian National Conference...· 0 citations
Ankle sprains frequently occur during walking and are often associated with excessive inversion at foot-ground contact. Although wearable ankle robots have advanced for mobility assistance, their application to injury prevention remains relatively unexplored. This paper presents a preliminary study of a smart wearable...
Hao Phan, Jorge Alvarez, C. Guevara et al.· IEEE International Symposium...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.