Skip to content
Review Open access

Hybrid Sliding Mode and Model Predictive Control for Robust Power Management in Mobile Robotic Systems

Aug 2026 · Algorithms · 0 citations · 24 references

Abstract

Mobile robots and autonomous vehicles require tightly regulated direct current (DC) power under rapidly varying load conditions, motivating control strategies that combine fast nonlinear regulation with predictive optimization. This paper proposes a Hybrid Sliding Mode Control and Model Predictive Control (Hybrid SMC + MPC) strategy for a DC-DC buck converter supplying a representative mobile-robot mission load. The controller employs a cascade SMC structure for fast inner-loop regulation and an MPC component that provides finite-horizon duty-cycle correction using planned load information. The MPC problem is formulated in condensed form and solved analytically without an external optimization solver. A Lyapunov-based analysis establishes a sufficient reaching condition for the sliding variable under the ideal averaged-model assumptions, and the condition is verified for the simulated mission. The proposed approach is evaluated in MATLAB using a 10-phase, 10 s load profile with resistance varying from 7 Ω to 100 Ω and is compared with SMC-only, MPC-only, PID, constant-duty, and reconstructed fuzzy-logic benchmarks. In the averaged-model study, the Hybrid SMC + MPC achieves a maximum absolute voltage deviation of 0.388 V, an RMSE of 0.0115 V, and a final-phase mean absolute error of 0.0076 V. It provides the lowest maximum voltage deviation among the principal closed-loop controllers, while PID achieves the lowest RMSE and final-phase error and SMC-only exhibits the shortest mean settling time. Relative to MPC-only, the Hybrid controller reduces the maximum voltage deviation by approximately 43.6% and the mean settling time by approximately 66.1%. An ablation study shows that the MPC contribution substantially improves overall and steady-state regulation accuracy, while load preview primarily reduces the worst-case voltage deviation. Switching-level MATLAB/Simulink validation with explicit 20 kHz PWM and converter parasitics confirms that the output remains within ±2% of the 25 V reference throughout the complete mission, with a maximum absolute deviation of 0.443 V and a maximum steady-state switching ripple of 21.6 mV peak-to-peak. These results demonstrate that the proposed Hybrid SMC + MPC architecture provides a favorable balance between worst-case transient regulation, steady-state accuracy, and predictive control capability for dynamically varying robotic power loads.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.