Sep 2026· 2026 International Russian Automation Conference (RusAutoCon)· pp. 231-237· 0 citations· 19 references
Abstract
In hot climates, the ambient air temperature can reach 45 °C and more, which leads to heating of the windings of power transformers above the permissible values and, accordingly, to a reduction in their relative service life. The purpose of the study is to determine the values of relative service life and the factors affecting it for different loading modes of transformer 20/6 kV. The tasks of the study are: conducting an analysis of the composition of electrical consumers included in the industrial zone, for example, in the Syrian Arab Republic (SAR), developing a method for assessing the overheating temperature of transformer elements depending on the load factor $(\mathrm{K}_{\mathrm{L}})$ and environmental conditions, developing an algorithm for assessing the relative service life of transformers 20/6 kV and developing a simulation model in MATLAB for the electrical power system of industrial zone fed by substation 20/6 kV. The value obtained from the simulation shows an approximate agreement with the value of average temperature of heating windings of transformers 20/6 kV with an error not exceeding 1%. It has been proven that when installing compensating devices in an industrial zone, the loading factor of transformers 20/6 kV decreases from 0.80 to 0.75 and the heating temperature of the transformer windings decreases from 92 °C to 90 °C, therefore, the relative service life of transformers increases from 0.5 to 0.63.
Relevance. New type of cooling of a power oil transformer with SF6 bubbles is proposed and therefore it is necessary to develop a mathematical model for selecting the optimal operating mode of a compressor bubbling SF6 gas. In the process of overheating of a power oil transformer, a cooling system is activated using fl...
A. Khismatullin· Bulletin of the Tomsk Polyte...· 0 citations
The purpose of the study is to develop and test a software-based calculation algorithm for automated assessment of the parameters for rural 0.4 kV power transmission lines, taking into account the 10/0.4 kV transformer, conductor parameters, the length of the supply section and agro-industrial facility loading. The met...
V. Konchin, V. Serebrovsky, I. Vornacheva et al.· Vestnik Kurganskoj GSHA· 0 citations
This article develops a mathematical model for assessing the technical condition of non-traction electrical systems of railway transport based on the operational indicators of transformer oil, as well as an algorithm for determining the integral value of technical condition. In the study, the water content, acid number...
D. Yusupov, B. Avazov, O. Kutbidinov· Международный научный журнал...· 0 citations
The article proposes a method for assessing the combined effect of variable solar irradiance, high temperatures, wind speed, partial cloud cover, dust accumulation, and power grid conditions on the reliability and energy generation potential of photovoltaic power plant equipment. A thermoelectric model for the PV syste...
Xurramov Bobir Sobir o'g'li, Baratov Laziz Suyun o'g'li· American Journal Of Applied...· 0 citations
Power transformers are essential components in electrical power systems, regulating voltage levels and ensuring efficient energy delivery. Although mineral oil has traditionally been used as an insulating and cooling fluid, growing concerns about its flammability and environmental impacts have encouraged the adoption o...
Sriyono, R. A. Prasojo, Jihan Fadhilah et al.· Sustinere: Journal of Enviro...· 0 citations