Segment-resolved assessment of hydration effects on liver water-specific T1 in comparison with T1-MOLLI and transient elastography

Aug 2026 · Quantitative Imaging in Medicine and Surgery · Vol 16, pp. 733-733 · 0 citations · 28 references
Medicine

TL;DR

Liver wT1 is physiologically modulated by hydration and exhibits spatial heterogeneity across liver segments, even in the healthy liver, and underscores the importance of whole-liver, segment-resolved wT1 mapping and physiological standardization when interpreting quantitative liver MRI.

Abstract

Background Quantitative liver T1 mapping is a promising noninvasive biomarker for diffuse liver disease, but it is influenced by physiological variability. Hydration alters tissue water content and perfusion, yet its effect on liver water-specific T1 (wT1) remains poorly characterized, particularly across liver segments. Prior studies relied on single-slice acquisitions, limiting assessment of spatial heterogeneity. The objective is to assess hydration-related changes in liver wT1 across all Couinaud segments using an accelerated multi-slice technique and to compare results with single-slice T1-modified Look-Locker inversion recovery (T1-MOLLI) and vibration-controlled transient elastography (VCTE). Methods Twenty-nine healthy adults underwent blood sampling, VCTE, and liver magnetic resonance imaging (MRI) after an ≥8-hour fast without fluid intake and again after ingestion of 1 L of water followed by a 1-hour equilibration period. Multi-slice wT1 mapping was performed using a Dixon-based continuous inversion-recovery Look-Locker (CIR-LL) sequence covering the entire liver in a single breath-hold. Single-slice T1-MOLLI and whole-liver proton density fat fraction (PDFF) and T2* mapping were acquired for comparison. Regions of interest (ROIs) were placed on PDFF, T2*, and wT1 maps in all liver segments. Statistical analysis included intraclass correlation coefficient (ICC; [2, 1]), linear regression, Pearson correlation coefficients Bland-Altman plots and paired two-sided t-tests. Results Hydration resulted in a higher global increase in mean liver wT1 (before: 773.4±63.2 ms, after: 800.3±66 ms) than T1-MOLLI (before: 853±68.8 ms, after: 861.6±55.9 ms). PDFF, T2*, and liver stiffness varied modestly within the physiological range. For liver stiffness, T1-MOLLI, and wT1, measurements obtained before and after hydration showed good agreement, with wT1 (y=0.9x+80.5, r=0.89, P<0.001) exhibiting a regression coefficient closer to that of liver stiffness (y=0.9x+0.7, r=0.63, P<0.001) than T1-MOLLI (y=0.6x+372.4, r=0.71, P<0.001). T1-MOLLI and wT1 showed good agreement under both hydration conditions (before: y=0.5x+355.7, r=0.64, after: y=0.8x+98.9, r=0.78), with T1-MOLLI yielding systematically higher values than wT1. Paired analysis demonstrated significant hydration-related changes in wT1 (P<0.001), with segment-wise wT1 increases remaining significant after correction for multiple testing. Furthermore, wT1 revealed spatial heterogeneity across liver segments. Conclusions Liver wT1 is physiologically modulated by hydration and exhibits spatial heterogeneity across liver segments, even in the healthy liver. These findings underscore the importance of whole-liver, segment-resolved wT1 mapping and physiological standardization when interpreting quantitative liver MRI.

Read PDF

Similar papers

Open access Oct 2026

Water-T1, PDFF, and T2* mapping of the liver using chemical shift-encoded MOLLI.

PURPOSE Hepatic MRI T1 relaxation time is a putative measure of fibrosis and inflammation but may be confounded by hepatic fat. This study evaluated a chemical shift-encoded Modified Look-Locker Inversion Recovery (CSE-MOLLI) technique for simultaneous water-specific T1 (water-T1), proton density fat fraction (PDFF), a...

Amol Pednekar, Joshua S. Greer, Pradipta Debnath et al. · 0 citations
Oct 2026

Myocardial T1 Mapping at 3 T: A Comparison of MOLLI and ShMOLLI across Healthy Volunteers and Various Cardiovascular Pathologies.

Background The clinical utility of quantitative T1 mapping in cardiac MRI is constrained by variability across acquisition protocols, and a comprehensive comparison between commonly used sequences remains unavailable. Purpose To provide a full range of cardiac MRI native T1 and extracellular volume fraction (ECV) value...

Hua-Ying Zhang, C. Cui, Wen-Li Zhou et al. · 0 citations
Open access Sep 2026

Native myocardial T1 mapping using rapid 1.5T T1FLASH and T1 MOLLI during breath-hold and free-breathing

Quantitative myocardial T1 mapping is an established technique in cardiovascular magnetic resonance (CMR). However, conventional T1 mapping requires relatively long breath-holds (BH), which may lead to breathing artifacts and reduced image quality in patients with limited BH capacity. The T1 fast low angle shot (T1FLAS...

L. Röwer, Yara Hussen-Demir, P. E. Verde et al. · 0 citations
Open access Aug 2026

Ex Vivo Measurement of Human Blood T1 at 5 T: Dependence on Hematocrit and Oxygenation.

Optimized and phantom calibrated MOLLI enabled rapid measurement of human ex vivo blood T1 at 5 T, and blood T1 at 5 T was higher than commonly reported adult values at 3 T and varied with both Hct and Y.

Shu-Wan Yu, Yuan Dong, Yu-Xiao Gu et al. · 0 citations
Open access Sep 2026

Impact of long-term fasting on liver and abdominal adipose tissues monitored by quantitative chemical-shift encoded MRI

Background and Aims This study used quantitative Magnetic Resonance Imaging (MRI) to explore lipid metabolism changes during a 12-day fasting intervention in the liver and abdominal adipose tissue (AT). Methods MRI was performed on 32 participants in the GENESIS clinical trial. This prospective, monocentric, single-arm...

M. Viallon, B. Leporq, Hélène Ratiney et al. · 0 citations
Open access Sep 2026

Free‐Breathing Arterial Spin Labeling MRI of the Kidney Using Flow‐Sensitive‐Alternating Inversion Recovery With Golden‐Angle Radial Sampling

Renal function critically depends on adequate perfusion. Arterial spin labeling (ASL) MRI enables noninvasive perfusion quantification but is highly susceptible to respiratory motion artifacts in renal applications. In this work, we developed and validated a free‐breathing renal ASL technique using flow‐sensitive alter...

Yi-Zhe Zhang, Wen-Yan Zhang, Song-Song Sun et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.