Oct 2026· Acta ophthalmologica· 0 citations· 25 references
Medicine
TL;DR
ICL implantation alters biometric measurements and theoretically predicted Δ-pSEQ; although these changes are statistically significant, their clinical significance is negligible.
Abstract
Objective
To investigate the effect of the implantable collamer lens (ICL) on biometric measurements and intraocular lens (IOL) power calculation formulas.
Methods
This prospective theoretical study included 92 eyes undergoing ICL surgery. Preoperative and 1-year postoperative biometric parameters, including axial length (AL), keratometry (K), anterior-chamber depth (ACD), lens thickness (LT), central corneal thickness (CCT) and corneal diameter (CD), were measured using IOLMaster 700. Nine formula types (10 variants) were evaluated: Barrett Universal II (BU II; BU IIa, IOLMaster 700-based; BU IIb, online calculator), Cooke K6, EVO, Hill-RBF, Hoffer QST, Holladay 1, Kane, Pearl-DGS and SRK/T. Primary outcomes were the difference in predicted spherical equivalent before and after ICL implantation (Δ-pSEQ) and the percentage of eyes within specified Δ-pSEQ ranges.
Results
For all eyes (n = 92), significant post-ICL changes included increased AL, steep K (K2), LT, CCT (+0.02 mm, +0.08 D, +0.26 mm, +0.003 mm; p = 0.031, 0.021, <0.001, 0.008) and decreased ACD (-0.28 mm, p < 0.001). ACD segmentation errors occurred in 34.78% of eyes, associated with low vault (optimal cut-off, 0.491 mm; AUC = 0.921). Eyes were grouped by segmentation accuracy (correct, n = 60; incorrect, n = 32). All Δ-pSEQ values were within ±0.50 D; between-subgroup differences in Δ-pSEQ ranges were not significant (p > 0.05). The highest proportions within ±0.25 D were SRK/T (86% overall, 94% incorrect group) and BU IIa (85% correct group); EVO had the lowest (71%-72%).
Conclusion
ICL implantation alters biometric measurements and theoretically predicted Δ-pSEQ; although these changes are statistically significant, their clinical significance is negligible. While incorrect ACD segmentation is common, it is unlikely to substantially affect the theoretical calculation results.
The SN60WF IOL model demonstrated better refractive prediction accuracy than the Softec model, and Formula selection according to IOL model may help improve refractive outcomes in eyes with shallow ACDs.
Ya-Li Wang, Wei-hua Lou, Lu Liu et al.· Bioengineering· 0 citations
PURPOSE
To investigate the long-term visual outcomes of the Implantable Collamer Lens (ICL) with a central hole (ICL V4c; STAAR Surgical) in eyes with an anterior chamber depth (ACD) of 2.6 to 2.8 mm.
METHODS
This retrospective, non-comparative, interventional case series included 41 eyes of 41 patients receiving ICL...
Hong-Yu Kong, Ling-Ling Niu, Jun-Feng Li et al.· Journal of refractive surger...· 0 citations
Purpose To evaluate the accuracy of intraocular lens (IOL) power calculation formulae incorporating posterior corneal power vs traditional keratometry in post-laser vision correction (LVC) eyes undergoing cataract surgery. Patients and Methods This multicenter study (7 sites) combined retrospective chart review and pro...
Hasan Alsetri, Mitchell P. Weikert, Nicole R. Fram et al.· Clinical Ophthalmology· 0 citations
Lenstar LS 900 optical biometry offers high predictive accuracy and efficient workflow in IOL power calculation in patients with age-related cataract in Iraqi patients having cataract surgery.
Omar Mahmood, Y. Al-Khafaji, Faraidoon Mohammad· Babcock University Medical J...· 0 citations
Purpose: To compare the refractive prediction accuracy of the SRK/T and Barrett Universal II intraocular lens (IOL) power-calculation formulas in uncomplicated phacoemulsification cataract surgery. Materials and Methods: This prospective comparative study included 200 eyes of 200 patients undergoing cataract surgery, i...
Pooja Srinivasan, Sozhamadevi Subramanian, S. Elavarasan et al.· Indian Journal of Clinical a...· 0 citations
Purpose To derive a regression formula estimating an individualized postoperative vault threshold associated with narrow-angle status from preoperative angle measurements and to evaluate an implantable collamer lens (ICL) sizing approach incorporating this formula. Patients and Methods This retrospective study included...