Skip to content
Open access

Quantitative Analysis of a Novel Systems-predicted Neutralizing Antibody Titer Assay 2305470

Jul 2026 · Journal of Immunology · Vol 215 · 0 citations

TL;DR

The SNAb assay could successfully multiplex hemagglutinin molecules to quantify the predicted neutralization of twelve analytes simultaneously and did not show an overcounting or undercounting of neutralizing antibody titers.

Abstract

Using systems serology, it is possible to create an assay that quantifies a human receptor’s binding levels to a virus receptor binding protein in the presence of neutralizing antibodies. For example, human influenza A virus predominantly binds to alpha 2’6-linked sialic acids, while avian influenza A prefers alpha 2’3-linked sialic acids. Modeling this binding in the presence of neutralizing antibodies using a systems serology approach would allow us to quantify neutralization breadth and capacity at a throughput and scale not previously known. Using four parameter or Michaelis-Menton fitted models, we can quantify the complete binding and complete inhibition of binding for virus receptor binding proteins and human receptor pairs at the multiplex level. From this, percent inhibition can be quantified, and a systems-predicted neutralizing antibody (SNAb) titer can be calculated. This titer was compared against existing neutralization assays and readouts for validation. This was done using serum and lavage samples from vaccinated/boosted non-human primates. Neutralizing antibody levels, whether they were measured by microneutralization assay, hemagglutinin inhibition assay, or SNAb were tightly correlated, and showed dependence on route of vaccination. The SNAb assay could successfully multiplex hemagglutinin molecules to quantify the predicted neutralization of twelve analytes simultaneously. The SNAb assay was performance-validated and did not show an overcounting or undercounting of neutralizing antibody titers. Neutralizing antibody levels can be quantified in an efficient way using a systems-based approach. This allows for the multiplexing of readouts in a high-throughput assay. The assay itself is built on four-parameter or Michaelis-Menton binding modeling, which does not bias the titer compared to other commonly used methods. National Institutes of Health Grant CA260476, PO1AI165072, and U19AI135995, and National Institutes of Health Contract 75N93021C00029 Technological Innovations in Immunology (TECH)

Read PDF

Similar papers

#protein folding Open access Aug 2026

Reconciliation of titer differences between SARS-CoV-2 neutralizing antibody assays

Three commonly used types of neutralization assay were compared and strong correlations and significant differences in measured neutralization between the different assays were found, highlighting areas for more precise and harmonized terminology and particular assay elements that must be considered in efforts to harmo...

E. Stadler, F. Mordant, Matthew J. Gartner et al. · 0 citations
Aug 2026

Validation of SARS-CoV-2 neutralization assay using VSV-based pseudovirus system.

The gold standard for SARS-CoV-2 neutralization assays involves wild-type virus, which requires Biosafety Level 3 (BSL-3) containment. To improve safety and accessibility, pseudovirus-based neutralization assays utilizing non-replicating particles like Vesicular Stomatitis Virus (VSV) expressing the SARS-CoV-2 spike pr...

A. Artarini, M. I. Tan, E. Giri-rachman et al. · 0 citations
Sep 2026

A Signal Turn-On DNA Proximity Assay That Correlates with SARS-CoV-2 Blocking Antibody Levels

Surrogate in vitro assays have enabled the scalable testing of neutralizing antibodies to SARS-CoV-2 as a toolbox to manage the post-COVID-19 situation and future outbreaks. However, most surrogate assays use a competitive format to mimic the blocking event between the receptor binding domain (RBD) and the human angi...

Shan-Ang Yan, L. L. Yung · 0 citations
Open access Aug 2026

A pseudovirus-based neutralizing antibody assay for measuring neutralizing antibody against rabies virus

The established pVNA assay for human rabies NAb detection has a detection capability similar to that of the gold standard RFFIT, but it has the advantages of reduced biosafety requirements, laboratory activity, and time, which highlight its safety, high efficiency, and feasibility for screening and monitoring rabies vi...

Xin-Xin Li, Pei Hu, Yueling Chen et al. · 0 citations
Open access Sep 2026

Establishment of a blocking ELISA for assessing neutralizing antibody levels against porcine epidemic diarrhea virus

A highly specific blocking ELISA was developed for serological diagnosis of porcine epidemic diarrhea (PED) using monoclonal antibodies (mAbs) against the S1 protein of PEDV. The S1 protein was expressed in HEK293F cells and used to immunize BALB/c mice. Through hybridoma screening, a high-affinity monoclonal antibody...

Pei-Yang Ding, Shuo-Qi Dong, Lin-Yi Bai et al. · 0 citations
Open access Sep 2026

Functional Evaluation of Neutralizing Antibodies Against Foot-and-Mouth Disease Virus Serotype O Using a Luciferase-Based Surrogate Neutralization Assay

The feasibility of the surrogate neutralization assay for assessing the functional activity of neutralizing antibodies and its potential applicability to vaccine immunogenicity assessment and functional antibody analysis is demonstrated.

Hyejin Kim, Dong-Wan Kim, Y. Chae et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.