Mass spectrometry-based chemical proteomics is a powerful method to analyze proteins labelled by small molecules to identify protein targets of active compounds and to profile protein post-translational modifications. The throughput and high protein input for chemical proteomics workflows has been often a limiting factor for application of the technology for specialized and difficult to culture cell lines. The high protein input was necessary to gain significant difference of noise to signal ratio in proteomics readout. Here, we describe a general chemical proteomics workflow, which is performed in 96-well plate and necessitate only 25 μg of protein input to profile post-translationally modified proteins including abundant O-GlcNAcylated proteins as well as low abundant AMPylated proteins. The workflow integrates advances in Cu(I)-catalyzed azide-alkyne cycloaddition to minimize chemical side-reactivity of the ‘click reaction’ and data-independent acquisition mode during LC-MS/MS measurement. An iterative optimization of protein clean-up on carboxylate-coated paramagnetic beads led to significant saving of the beads usage and lowers the unspecific protein background that resulted in sensitivity gain.
Improvements enabling quantification of site-specific modifications, including post-translational modifications and covalent compound-protein interactions spanning diverse pathways are described.
Steven R. Shuken, Geordon A. Frere, Charlotte R. Beard et al.· Nature Communications· 0 citations
A scalable workflow for the deep proteomic analysis of low- to ultralow-input samples by systematically optimizing a widely adopted Orbitrap and UHPLC platform to maximize sensitivity, precision, and throughput is developed.
Dongyoon Shin, Sumin Lee, S. Yang et al.· Analytical Chemistry· 0 citations
These findings imply that S-TRAP is the preferred choice for discovery-phase proteomics (biomarker hunting), while TG or SG should be prioritized for high-precision validation studies.
D. Viala, R. Maillet, A. Delavaud et al.· Omics· 0 citations
It is anticipated that TDP, enhanced by ultralow-flow PLOT chromatography columns coupled to MS, could be a supplementary or an alternative approach for limited-sample analysis, as it eliminates the need for protein digestion and minimizes sample cleanup, enabling rapid sample preparation while preserving proteoform in...
Yunfan Gao, Michal Greguš, James C. Kostas et al.· Analytical Chemistry· 0 citations
This chapter provides an overview of the biological roles and structural diversity of SUMOylation, and presents an MS-based workflow designed to identify SUMOylation sites with high specificity and depth.
Chongyang Li, P. Thibault· Methods in molecular biology· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.