Skip to content
Open access

A drift‐aware framework for reliability assessment and image‐based interpretation of atomic force microscopy measurements

Aug 2026 · Journal of Microscopy · Vol 303, pp. 312 - 326 · 0 citations · 51 references
Medicine

TL;DR

The results indicate that the proposed framework should be positioned not as a universal drift‐correction method, but as a complementary and modular analysis approach that supports the drift‐aware interpretation, comparison, and reliability assessment of consecutive AFM topography measurements.

Abstract

Drift is one of the primary sources of uncertainty limiting the accuracy, repeatability, and reliability of scanning probe microscopy (SPM) measurements, with a particularly significant effect on the comparison of consecutive surface topography images. In this study, a two‐module hybrid physical–computational framework is presented for the drift‐aware interpretation and reliability assessment of consecutive AFM topography measurements. The first module integrates deep learning (DL)‐based inter‐frame correspondence extraction, geometric validation, physical coordinate reconstruction, scan‐order‐based acquisition‐time assignment, inter‐scan delay correction, and temperature synchronisation to generate a time‐labelled drift representation. The second module uses this structured representation for comparative data‐driven modelling and evaluates drift velocity ( vd$v_d$ ), model performance, and stability through temperature‐included and temperature‐excluded configurations. This structure enables the joint analysis of validated correspondences in terms of lateral displacement, relative height variation, acquisition time, vd$v_d$ , drift direction, and synchronously recorded ambient temperature, together with their physical coordinate labels. The results indicate that the proposed framework should be positioned not as a universal drift‐correction method, but as a complementary and modular analysis approach that supports the drift‐aware interpretation, comparison, and reliability assessment of consecutive AFM topography measurements.

Read PDF

Similar papers

Open access Sep 2026

A computational framework for post-acquisition stability assessment in scanning tunneling microscopy

The proposed approach combines deterministic computer vision-based analyses with modern deep learning components in a hybrid workflow, producing pixel-level drift metrics together with local and surface-level image-similarity indicators based on the structural similarity index measure and normalized cross-correlation.

D. Deveci, Ö. Ünverdi, F. Yıldırım et al. · 0 citations
Preprint Sep 2026

Universal Drift Correction for Multidimensional Scanning Microscopy

In scanning microscopy, drift causes the specimen to be sampled at positions displaced from the nominal probe positions. This displacement alters the spatial assignment of the recorded signals and biases quantitative measurements across two-dimensional imaging, channel-resolved spectroscopic mapping, and scan-position-...

Sangjoon Lee, William Millsaps, Da-Woon Yoon et al. · 0 citations
Open access 2026

Enabling Bias-Dependent Electronic Morphology Analysis of Single Molecules in STM via Deep Segmentation with Noise-Aware Calibration

: Scanning tunneling microscopy (STM) images are frequently affected by low-frequency vibrations, substrate-induced background variations, and bias-dependent contrast changes, which degrade molecular feature responses and hinder reliable segmentation. To address this challenge, we develop an STM-oriented Feature Pyrami...

Lingtao Zhan, Jia-Le Zhu, Tingting Wang et al. · 0 citations
Preprint Sep 2026

Real-Time Atomic-Resolution Electron Phase Imaging without Probe Calibration via Ptychography-Supervised Learning

Atomic-scale phase imaging is central to resolving defects, interfaces, and weakly scattering atoms that govern the behavior of nanoscale materials. Electron ptychography delivers sub-{\aa}ngstr\"om phase sensitivity but remains an offline technique, because its iterative reconstruction is computationally expensive and...

H. Yue, Charles B. Chen, C.-N. Hsiao et al. · 0 citations
Sep 2026

Blur-guided conditional diffusion for robust correlation in fast-scanned digital images of in-situ SEM tensile testing

This study proposes a blur-guided conditional diffusion framework for restoring noisy in-situ scanning electron microscopy (SEM) images acquired with a reduced number of scan accumulations for accurate measurement of material properties, focusing particularly on structural and edge preservation under fast-acquisition c...

Hyeon-Gyu Min, Jun-Hyub Park · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.